Door Design · J-2009
Fluted Steel Entry Door with Aluminum Panel
J-2009 runs a vertical fluted aluminum panel down the centre of a steel leaf, so the entrance shows a fine ribbed shadow at close range and a clean edge from the street. J-2009 is manufactured as a single door on a steel system with an aluminum trim. Nothing is cut until the opening is surveyed, and the powder-coated steel with a lacquered or wood-grain face is signed off against a sample.
70 mm door leaf and 90 mm frame; final configuration and overall frame dimensions are confirmed on your project drawing. Multi-point lock with anti-drill cylinder, and a fingerprint lock can be fitted on request.
Discuss This DesignWhy this design works
- Vertical fluting pressed at constant depth
- Flush pull leaves the ribbing uninterrupted
- Steel core for apartment and townhouse entrances
Design details
- Style
- Modern fluted
- Material / system
- Steel system with aluminum trim
- Configuration
- Single door
- Door leaf thickness
- 70 mm
- Frame depth
- 90 mm
- Maximum frame sizes by configuration
- Single: 1180 × 2500 mm; unequal double: 1580 × 2500 mm; equal double: 2180 × 2500 mm (overall frame; family limits)
- Core filling
- Aluminum honeycomb or foam filling, selectable
- Glass
- None, solid panel
- Locking
- Multi-point lock with anti-drill cylinder
- Smart lock
- Smart lock compatible
An Aluminium Panel Set Into a Steel Leaf
Two metals in one leaf: a fluted aluminium panel down the centre, steel either side. The panel is the only place the door shows a fine ribbed shadow, and it reads at close range precisely because the surrounding steel is smooth. What makes or breaks it is the margin — the width of steel left at each side. Set the panel and margins as a ratio of the leaf width and the entrance looks composed; set the panel to a fixed width and the margins change with every opening size.
The two metals also move differently. Aluminium expands roughly twice as much as steel over the same temperature range, so the panel cannot be a tight fit in the steel opening — it needs a movement allowance at its edges, usually read as a shadow gap. That gap is why the panel looks deliberately inset rather than flush, and it is the detail to protect when the finish is changed late in the project.
Specification & ordering
Steel Entry Door Specifications and Ordering
Steel entry doors are quoted by sheet thickness, frame build and core, because those three numbers decide the weight, the security performance and the freight cost per door.
Maximum Frame Sizes by Door Construction
Width × height in millimetres, measured to the outside of the frame. Arched heights include the arch. Confirm the selected model, clear passage and any additional sidelights on the project drawing.
| Door construction | Single leaf | Unequal double leaf | Equal double leaf |
|---|---|---|---|
| Steel Entry Doors | 1180 × 2500 mm | 1580 × 2500 mm | 2180 × 2500 mm |
These are construction-family limits, not confirmation that every pictured design is available in every arrangement. Pivot doors are supplied as a single leaf only; unequal and equal double pivot doors are not offered. Fixed sidelights are separate from the opening leaf.
Technical specification
- Door leaf
- 1.0 mm galvanized steel sheet
- Frame
- 2.0 mm galvanized steel
- Core
- Aluminum honeycomb or water-based polyurethane foam as standard; fire-rated MGO board for project orders
- Configuration
- Single or double leaf, with or without glass
- Glazing
- None, solid panel
- Finish
- Wood-grain transfer, powder coat or custom finish
Ordering & supply
- Minimum order quantity
- 1 door for seven series. Steel Entry and Fire Rated: 1 door for custom orders, 5 doors for project orders.
- Sample lead time
- 25 days
- Production lead time
- 30–45 days
- Container loading
- Approx. 300 doors per 40HQ (2050 × 950 mm single leaf)
- Factory inspection
- Third-party factory inspection welcome
- Trade terms
- FOB Shanghai / Ningbo; Yiwu warehouse handover; DDP available
- Warranty
- 3 years on structure; 1 year on hardware and electronic lock components
Figures above are our standard build. Where a project falls outside them, we quote a custom variant against your drawings rather than build to the nearest catalogue size. Full series specification: Steel Entry Door.
Image gallery
Frequently asked questions
Does the fluting collect dust?
The ribs are pressed into the panel and coated with the face, so they wipe clean.
Can the fluted panel be full height?
Yes, the panel can run the full leaf height or stop at a horizontal rail; specify on the drawing.
Can this design be custom sized?
Yes. Every JMR Habitat door is built to the opening dimensions on your survey or drawing, including non-standard widths and heights.
Which materials and finishes are available?
This design is built in Steel system with aluminum trim. Powder-coated colours, wood-look and metallic finishes are available, and a physical sample can be approved before production.
How do I specify this door for a project?
Send the opening dimensions, a drawing or reference image and your finish direction through the inquiry form; the team returns a specification and drawing for approval.
Related designs
Planning an entrance around this design?
Share your opening dimensions, finish preferences and configuration needs with our team.
Start an inquiry
JT-02
J-2002
J-2006